UPS 10KVA | BCN EXTRA POWER TOWER MYRIA 10kVA/10kW

Short Description

 The Ultimate Power Protection for Enterprise & Server Rooms Never worry about power outages again. The BCN EXTRA POWER TOWER MYRIA 10kVA is a premium True Online Double Conversion UPS engineered to deliver clean, uninterruptible power with zero transfer time (0ms), delivers 9-10kW stable power for servers. Supports flexible 3:3, 3:1, and 1:1 phase setups. High 96% efficiency with 3-Level IGBT. It completely isolates your critical equipment from voltage drops, surges, and electrical disturbances.

Wishlist
Key Features
  • 100% True Online Double Conversion UPS: Delivers continuous power conversion with Zero Transfer Time (0ms), providing reliable protection for critical equipment against power outages, voltage drops, overvoltage, power surges, and electrical disturbances.
  • High Power Capacity – 10kVA / 10kW UPS: Supports up to 10,000W of real power with the optional PF 1.0 configuration. Provides stable and reliable power for server rooms, IT infrastructure, and enterprise-level critical equipment. The standard PF 0.9 configuration delivers 9,000W. 
  • Flexible 3-Phase and Single-Phase UPS Configuration: Designed for versatile electrical installations, supporting UPS 3:3 (3-Phase Input / 3-Phase Output), UPS 3:1 (3-Phase Input / Single-Phase Output), and UPS 1:1 (Single-Phase Input / Single-Phase Output) configurations to accommodate different commercial and industrial power requirements.
  • Advanced 3-Level IGBT Technology: Equipped with high-performance 3-Level IGBT inverter technology to improve power conversion efficiency, minimize harmonic distortion, and deliver clean, stable power to sensitive electronic equipment.
  • High Energy Efficiency up to 96%: Reduces energy losses, heat generation, and operating costs. Supports ECO Mode for additional energy savings and Emergency Power Off (EPO) functionality for enhanced operational safety.
  • Wide Input Voltage Range: Operates within an extended input voltage range of 80–280VAC (L-N) / 138–485VAC (L-L), helping maintain stable UPS operation during voltage fluctuations while reducing unnecessary battery discharge.
  • Advanced Dual DSP Digital Control: Features a dual Digital Signal Processor (DSP) control system for precise power management, enhanced operating stability, and reliable 24/7 performance.
  • Flexible Battery Configuration: Supports adjustable battery configurations with internal batteries and external battery cabinets, allowing businesses to customize backup runtime based on their power requirements, operational needs, and budget.
  • Smart Monitoring and Parallel Operation (Optional): Supports optional SNMP network monitoring for remote UPS status management and optional parallel operation for system capacity expansion or N+X redundancy, subject to compatible configurations.

Technical Specifications – BCN EXTRA POWER TOWER MYRIA 10kVA

  • Model: BCN EXTRA POWER TOWER MYRIA 10kVA
  • UPS Technology: True Online Double Conversion, Transformerless Design
  • Rated Capacity: 10,000VA / 9,000W (Standard Output Power Factor 0.9)
  • Optional Rated Capacity: 10,000VA / 10,000W (PF 1.0 Option)
  • Electrical Configuration: 3:3 (Three-Phase Input / Three-Phase Output), 3:1 (Three-Phase Input / Single-Phase Output), and 1:1 (Single-Phase Input / Single-Phase Output)
  • Input Voltage Range: 80–280VAC (L-N) / 138–485VAC (L-L)
  • Input Frequency: 50Hz ±10%
  • Input Power Factor: 0.95
  • Input Current Harmonic Distortion (THDi): Less than 3%
  • Output Voltage: 220/230/240VAC or 380/400/415VAC, depending on the electrical configuration
  • Output Voltage Regulation: ±1%
  • Output Frequency: 50/60Hz ±0.1%
  • Output Voltage Harmonic Distortion (THDv): Less than 2% for Linear Loads and less than 4% for Non-Linear Loads
  • Maximum Efficiency: Up to 96%
  • Energy-Saving Mode: ECO Mode Supported
  • Battery Voltage: Default ±96VDC, adjustable from ±96VDC to ±240VDC
  • Internal Battery Configuration: Supports 16–40 units of 12V 7Ah batteries
  • Battery Charging Current: Default 4A, adjustable from 1A to 10A
  • Standard Communication Interfaces: RS485, Emergency Power Off (EPO), Dry Contact
  • Optional Communication Interfaces: RS232, SNMP Network Management Card
  • Protection Functions: Overload Protection, Short-CircuitProtection, Low Battery Protection, Over-Temperature Protection
  • Ingress Protection Rating: IP20
  • Operating Temperature: 0–40°C
  • Dimensions (W × D × H): 250 × 755 × 880 mm
  • Net Weight (Without Batteries): 50 kg
  • Supplier and Service Provider: BT Connect – Professional UPS Consultation, System Design, Installation, and After-Sales Support in Thailand

Applications – Where to Use BCN UPS 10kVA

  • Enterprise Server Rooms and Server Racks: Provides continuous, stable power for business servers, storage systems, and critical IT infrastructure, helping prevent unexpected downtime and potential data loss.
  • Network Infrastructure and Security Systems: Protects network switches, routers, firewalls, CCTV surveillance systems, and communication equipment from power interruptions and voltage fluctuations.
  • Retail POS and Business Operations: Maintains reliable backup power for point-of-sale systems, inventory management equipment, and essential business applications, minimizing operational disruptions during power outages.
  • Industrial Automation and Manufacturing: Protects industrial control systems, automation equipment, PLCs, and sensitive electronics from power surges, unstable voltage, and unexpected electrical disturbances.
  • Healthcare IT Systems and Medical Facilities: Provides backup power for hospital IT infrastructure, clinic information systems, and compatible medical equipment. Engineering assessment is recommended to ensure compliance with specific equipment and healthcare electrical requirements.

 Download Catalog: BCN UPS EXTRA POWER MYRIA 10-40KVA

Why Choose BCN UPS 10kVA Over Other UPS Brands?

When comparing commercial and industrial UPS solutions, the BCN EXTRA POWER TOWER MYRIA 10kVA stands out for its flexible electrical configurations, energy-efficient technology, and customizable battery solutions.

- Greater Flexibility for Single-Phase and Three-Phase Power Systems: Unlike UPS models designed for only one fixed input/output phase configuration, the BCN UPS 10kVA supports 3:3, 3:1, and 1:1 electrical configurations. This flexibility helps businesses select a suitable power protection solution for different installation environments and future infrastructure requirements, subject to the supported model configuration.

- Advanced Energy-Efficient UPS Technology: Featuring 3-Level IGBT technology and operating efficiency of up to 96%, the BCN UPS helps reduce power losses, heat generation, and long-term electricity expenses. Its ECO Mode provides an additional energy-saving option for organizations seeking lower operating costs.

- Customizable Battery Backup Solutions: The flexible battery configuration allows engineers to optimize battery quantity and capacity according to the required backup runtime and available budget. Businesses can select suitable internal battery arrangements or external battery cabinets without unnecessary investment in oversized battery systems

 

 

Ratings & Reviews
There are no ratings and reviews yet. Be the first to comment.
เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว and นโยบายคุกกี้